<LOGO>
FM Transmitter Measurement Report
Created: 2024-01-20 04-50-13
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 42 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 42 kHz 19060 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,2 dBr -0,60 dBr -0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 4:50, 20.01.2024
RT
"Pribehy 20. stoleti - Tisice zaku a studentu se loni zucastni..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 42 kHz MIN: 6 kHz % above 77 kHz: 0,0000 Acquired: 2024/01/20 4:50:10 Total samples: 19060 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: -0,1 dBr MIN: -1,2 dBr AVE: -0,60 dBr % above 0,2 dBr: 0,0 Last value: -0,5 dBr (2024/01/20 4:50:10) 04:36 04:38 04:40 04:42 04:44 04:46 04:48 04:50 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality